The ADMT-300S-X has two different configurations, and different configurations will give great performance hints
A:300S-X/600S-X/1200S-X/3000S-X single channel Standard Configuration

B:ADMT-300S-X 600S-X/1200S-X/3000S-X is optionally equipped with a wireless sensor probe
C:The standard and optional complete configurations are as follows:
Type-1 Standard configuration Parts List
- mainframe(Touch Screen) X1
- Electrode X2
- 10m measurement cable X1
- charger X1
- Data export line x1
- Aluminum box X1
- Warranty card X1
Type-2 Standard configuration Add optional wireless sensor probe Parts List
- mainframe(Touch Screen) X1
- Electrode X2
- 10m measurement cable X1
- charger X1
- Data export line
- Aluminum box X1
- Warranty card X1
- Additional Wireless sensor X1
Type-2 Add a wireless sensor probe Aluminum box
The detailed operation process is as follows:
1-Connect the electrode to the 10m measuring Cable:
Generally, the 10m measuring line is fully expanded. If the measuring site is very small, the 10m measuring line can also be shortened, as shown in the video
2-After confirming the first measuring point, it is necessary to move to the next measuring point until the measurement of the last measuring point is completed
- The measuring point is always at the midpoint of the 10m measuring line. If you change the length of the measuring line, the measuring point will also be at the midpoint of the measuring line. Here we will mainly talk about the 10m length as an example
- When moving to the next measuring point, all the following measuring points need to move the same distance and keep moving at the same distance, so the data obtained is correct
3-The detector can select 2 different measuring tools for measurement
- For wire measurement, electrode rod measurement should be selected as the measurement mode. This is a standard configuration option. At least 2 people are required to complete the measurement
- When encountering a hard ground or a small measuring area, you can use the optional wireless probe to complete the corresponding measurement work. This is the advantage of the wireless probe. Usually, we recommend customers to consider increasing the configuration of the wireless probe
4-The measurement results can be directly sent to the engineer for analysis
The correct parameters need to be set before measurement. If the parameters are incorrect, the engineer can quickly see them and help you correct them
Get the final 2D/3D map and send it directly to the engineer for analysis
5-ADMT-300S-X And ADMT-600S-X/1200S-X/3000S-X Same and different
Model | ADMT-300S-X | ADMT-600S-X | ADMT-1200S-X | ADMT-3000S-X |
Adjustable depth | 100/200/300m | 100/200/300/400/600m | 100/200/300/400/500/600/800/1200m | 200/300/400/500/600/800/1200/2000/3000m |
Display | 2D/3D | 2D/3D | 2D/3D | 2D/3D |
Measurement Mode | MN/TT(Option) | MN/TT(Option) | MN/TT(Option) | MN/TT(Option) |
6-ADMT-300S-X ADMT-600S-X/1200S-X/3000S-X New 7 Inch Touch Screen underground water detector How to use it?
7-ADMT-300S-X ADMT-600S-X/1200S-X/3000S-X 3D Underground water detector mainframe How to use it
8-ADMT-300S-X 600S-X 2-year warranty and free lifetime technical service support
Technical service support can be contacted via Wechat QR Code or Whatsapp QR Code, or you can call us at Tel:+86-13227326207